Masters distinguish typical malfunctions from Virpul refrigerators, because some breakdowns in them occur more often than in other brands. In the article we will analyze the reasons why he suddenly stopped working.
Causes and signs of damage
If you pay attention to the symptoms of a malfunction, then you can approximately determine the breakdown. Refrigeration equipment (CW) from the company "Virpul", although it is notable for quality, is not insured against breakdowns. The malfunction of the control board is considered the most serious.
What causes a breakdown:
- voltage drops in the network;
- moisture contact;
- other damage, such as during transportation.
How to identify a problem? In some cases, the refrigerator and the freezer may not work in the refrigerator, the indicators do not light. Sometimes the motor-compressor fails, then there is no cooling in the chambers. If one of the circuit board elements burns out, you may smell a burning smell.
Well, if the control unit can be repaired, then the master will do a flashing. The module itself in imported models is expensive, sometimes it is more profitable to buy new equipment.
Freon leak
The malfunction can be found in any Whirlpool models: ARC 8140, APC 4020, 4020 1 IX and others. Most often, a leak occurs in the freezer section.
Unfortunately, it is difficult to independently detect the release of freon, since this is gas. Pay attention to such signs:
- does not freeze a freezer or refrigerator;
- motor-compressor runs non-stop;
- the refrigerator turns off if the gas is completely leaked;
- Virpul refrigerator 4020 (and other models) beeps, blinks with an alarm indicator, which indicates the absence of cooling in the chamber.
In the event of a leak, you must call the wizard, who will repair it and charge the system with refrigerant.
Problems with the thermostat
A malfunction in the temperature controller or temperature sensor is associated with the electronics. A common cause of sensor failure is an open circuit. To check this, use a multimeter. If the sensor contacts are closed, then it needs a replacement.
Symptoms of a similar malfunction:
- The light in the camera is on, but the refrigerator is not working.
- The technique works, but a light flashes on the panel, which means that the temperature in the chamber is too high. If there is a display, an error code is displayed.
If the temperature controller is not working properly, the system receives inaccurate temperature data. Signs:
- One or both compartments do not cool products well.
- An alarm sounds, the refrigerator beeps or reports an elevated temperature by blinking a light bulb.
It may be the other way around, when the departments in the cold weather start to freeze excessively, despite the set temperature. Depending on the cause of the breakdown, you can replace the sensor contacts or the thermostat itself.
System blockage
If you notice that water is dripping in the compartment, the cause is probably condensation. Depending on the type of defrosting, condensation occurs for various reasons. To identify a malfunction with the Know Frost system, pay attention to the following symptoms:
- The compressor is constantly running, pumping cold into the chamber. Snow forms on the walls of the freezer.
- There is not enough cold in the refrigerator compartment while the fan is running. Drops of water run off the freezer along the back wall.
- The system alerts you of elevated temperatures with an audible signal.
In Virpul HO with a drip system, water accumulates under the lower drawers, snow freezes on the walls.
As the drainage hole is clogged, moisture has nowhere to go. It accumulates in the chamber, after which it freezes, creating a snow and ice cover. The problem must not be left to chance, as this can lead to the failure of the defrost system in the refrigerator.
If you notice such malfunctions in your Virpul refrigerator, do not start the problem. It’s much cheaper to fix the problem right away than to deal with its consequences.